KARBOMİT


Karbomit Panel Tile Sheet



KARBOMİT


Technicial Spesifications

 


Technicial Spesifications 
Width890 mm1040 mm
Useful width800 mm955 mm
LengthDesired LengthDesired Length
Thickness2 mm / 2,5 mm / 3 mm2 mm / 2,5 mm / 3 mm
Weight

2,0 mm : 3,30 Kg/m²
2,5 mm : 4,10 Kg/m²
3,0 mm : 4,95 Kg/m²

2,0 mm : 3,30 Kg/m²
2,5 mm : 4,10 Kg/m²
3,0 mm : 4,95 Kg/m²

Groove height25 mm
Purlin range700 mm - 800 mm

TOLERANCE

Thickness: ± 0.05 mm

Useful width: ± 3 mm

Length: ± 5 mm

 

 

 

 
Tile Sheet


Accessories and Installation Guide


1-1-en
1-2-en

1

Karbomit Panel Tile Sheet :

First of all, the slope of the roof should be at least 15 degrees and at most 35 degrees.

The purlin spacing should be 70 cm.

Overlap the boards and mount from the overlap point as much as possible.

1-3
2

2

Top Ridge :

In order for the top ridge to be applied properly, the gutter heights of the main boards on both sides of the roof must overlap. The top ridge must then be mounted to the panel boards onb both sides.

3

Side Ridge :

It is used in the edge joints of panel sheets up to the top the roofs in versatile roofs. The ridge should be placed properly so that it closes on both sides.

4

Three-armed ridge :

It is used at the junction points of side ridges and top ridges. In order to apply this ridge, the other ridges must be aligned with each other.

3
5

5

Closing Ridge :

It is used to close the end of other ridges after the assembly is finished.